12.2.5 Tape Speed Adjustment

TOP PREVIOUS NEXT

  1. Connect a frequency indicator. (Cf. Fig. 12)

  2. Playback the middle portion of the test tape (QZZCWT).

  3. Adjust the motor volume so that the following output level is produced. (Cf. Fig. 16)

    Adjustment Range: 3,000 ± 90Hz (a constant speed)


TOP PREVIOUS NEXT