11.2 Operation Check without Cassette Tape

TOP PREVIOUS NEXT

  1. Pull up the EJECT lever using a rubber band. (Cf. Fig. 6)

  2. Supply DC5V to MOTOR. (→ MOTOR rotates.)

  3. Lift up the mechanism unit’s plunger/rib with the tip of a negative screwdriver, and operate the unit in the same timing as
    supplying the power. (Cf. Fig. 7)


TOP PREVIOUS NEXT