2.4 When the 10A fuse is blown due to the operation of the short switch:

TOP PREVIOUS NEXT

WARNING

When the 10A 250V fuse is blown due to the operation of the interlock monitor switch, replace all of the components (primary latch switch, secondary latch switch, short switch and power relay B (RY1)).

  1. This is mandatory. Refer to “adjustments and measurements” for the location of these switches.

  2. When replacing the fuse, confirm that it has the appropriate rating for these models.

  3. When replacing faulty switches, be sure the mounting tabs are not bent, broken or deficient in their ability to hold the switches.